Lab automation and robotics

What Reeflex does not claim here

  • Reeflex is not a safety system and must never be described as one. Safety functions are SIL-rated hardware / safety-PLC logic (IEC 61508, ISO 13849). Reeflex is a defence-in-depth layer above the safety PLC, at the agent boundary: it decides whether the agent may issue the command. The SIS stays the last line.
  • Supervisory level only. Setpoints, modes, recipes, firmware, missions — not the control loop (milliseconds).
  • Verdict ≠ outcome. Reeflex records the decision and the declared magnitude; it does not read sensors. Attest says so, as it does for IT evidence (received vs occurred).
  • envelope_fraction and safety_function are the adapter's declarations. A wrong safe range in a mapping is a wrong verdict — mapping files are controlled documents, and the docs say so.

The situation

A research group lets an agent run experiments end to end: it plans a run, programs the liquid handler, doses reagents into a reactor, and moves samples with a robot arm, through the instruments' MCP servers. Reeflex sits in that tool path.

What goes wrong without a gate

A planning error turns into material in one step. A unit mistake (mL for µL) in a dose is a thousand-fold overdose, executed in seconds, and a dispensed reagent cannot be un-dispensed. An agent retrying a failed step will retry it again, and each retry is another real dose.

Three representative actions

Moving a plate between deck positions. A reversible, non-parametric motion — the arm can move it back. Allowed, and counted.

Verdict: allow · rule reeflex.policy/default_allow

{
  "agent":     { "id": "agent:lab-runner", "session_id": "sess-run-2291" },
  "action":    { "namespace": "robot", "verb": "actuate", "ability": "arm/move_labware" },
  "target":    { "kind": "deck_position", "ref": "deck.B2", "environment": "production",
                 "safety_function": false },
  "magnitude": { "count": 1 },
  "axes":      { "reversibility": "reversible", "blast_radius": "single", "externality": "physical" },
  "approval":  { "present": false }
}

Dosing a reagent into the reactor. An irreversible physical effect on the live rig: R9 holds it for the scientist on duty, who sees the declared quantity and approves or rejects.

Verdict: require_approval · rule reeflex.policy/physical_irreversible

{
  "agent":     { "id": "agent:lab-runner", "session_id": "sess-run-2291" },
  "action":    { "namespace": "pump", "verb": "actuate", "ability": "dosing/dispense" },
  "target":    { "kind": "reactor", "ref": "reactor.R2.inlet_a", "environment": "production",
                 "safety_function": false },
  "magnitude": { "count": 1,
                 "physical": { "envelope_fraction": 0.3, "unit": "mL",
                               "requested": 15.0, "range": [0.0, 50.0] } },
  "axes":      { "reversibility": "irreversible", "blast_radius": "single", "externality": "physical" },
  "approval":  { "present": false }
}

Disabling the enclosure's door interlock to "speed up the run". The interlock is a safety function. Overriding it in production is refused under R8, with no approval path.

Verdict: deny · rule reeflex.policy/safety_function_override_prod

{
  "agent":     { "id": "agent:lab-runner", "session_id": "sess-run-2291" },
  "action":    { "namespace": "robot", "verb": "override", "ability": "enclosure/set_interlock" },
  "target":    { "kind": "interlock", "ref": "cell1.door_interlock", "environment": "production",
                 "safety_function": true },
  "magnitude": { "count": 1 },
  "axes":      { "reversibility": "reversible", "blast_radius": "single", "externality": "physical" },
  "approval":  { "present": false }
}

The same dose against the instrument's simulator (environment: dev) is not held — a dry run is the place for the agent to find its unit mistakes.

Verdict: allow · rule reeflex.policy/default_allow

{
  "agent":     { "id": "agent:lab-runner", "session_id": "sess-sim-2291" },
  "action":    { "namespace": "pump", "verb": "actuate", "ability": "dosing/dispense" },
  "target":    { "kind": "reactor", "ref": "reactor.R2.inlet_a", "environment": "dev",
                 "safety_function": false },
  "magnitude": { "count": 1,
                 "physical": { "envelope_fraction": 0.3, "unit": "mL",
                               "requested": 15.0, "range": [0.0, 50.0] } },
  "axes":      { "reversibility": "irreversible", "blast_radius": "single", "externality": "physical" },
  "approval":  { "present": false }
}

How to deploy it

reeflex-mcp in front of each instrument's MCP server. The mapping declares dispense and dose tools as actuate with reversibility: irreversible; the line that matters is that one — it is what makes R9 hold the dose instead of counting it.

What Reeflex does NOT do here

  • It does not check the chemistry. A dose inside the declared range, of the wrong reagent, is a dose inside the declared range.
  • It does not measure what was dispensed. The verdict is about the command; the instrument's own log is the record of what happened.
  • It does not stop the arm mid-motion. Light curtains, force limits and the E-stop are the cell's safety functions and act at their own speed.
  • A tool mapped reversible that is not, is a dose R9 never sees. The mapping is a controlled document.